The air conditioner condensing unit is one half of the cooling cycle with the evaporator coil. The condensing unit’s occupation is to diffuse and reject heat, while the evaporator coil absorbs heat. All HVAC technicians learn this as the original step in their cooling education. The condenser is located in the huge boxy exterior unit at most buildings. Heat pumps also use condensers, but most persons North of Denver do not use heat pumps because the efficacy of heat pumps decreases as the temperature drops.

The condenser along with the compressor is the main transferor of heat amongst the outside air and the air blowing through your house. To do this, the compressor must be sealed inside the cooling cycle, and that is why compressor replacements are so common. It is very hard to undertake and repair something that is sealed within the system. On the other hand, there are a lot of things you may do to try and maintain the life of your condensing unit. If not the right way maintained, the condenser and most other air conditioning constituents will go into a downward spiral before they self destruct. As the elements become worn and less efficient, the compressor and blower motor will start out working harder to try and keep cooling in spite of scaled down ability. Eventually elements overheat and fail.

One thing you may do to maintain your Denver HVAC system to to check the outside cooling unit before summer starts and it is in heavy use. I commend calling a Denver air conditioner company to carry out the check, but if you feel handy and know how to operate around electricity, then go ahead. The original step before doing any work on a condensing unit is to shut of the breaker supplying electricity to the unit. Spin the fan and see if it turns. Then turn on the power and switch on the thermostat and make sure the fan starts blowing upward a good deal. A mutual problem with these condenser motors is bearing failure, which will stop the fan from spinning properly.

The main reason you want to check the condenser fan motor before you operate the system is because it is connected to the compressor. A failure at the fan may overload the compressor, and the compressor is a much more pricey portion than the condenser motor.

Just like evaporator coils, condenser coils may build up dirt and gunk which will decrease efficiency. Just like everything else in central air, as efficacy goes down, the system tries to work harder to compensate until it fails. The solution is to call an air conditioning services Denver company to clean the condenser coils. You may also do it yourself, but you will need to turn the thermostat and breaker off and pull the plug on the condenser electrical box. You will need to spray the condenser with sufficient pressure to remove dirt without bending the fins. A little soap may help too. The key to preserving performance with these units is maximizing airflow. So the condenser must be clean and the exterior unit ought to have clear airflow.


Air Conditioner Unit

Air Conditioner Unit Image

Air Conditioner Unit

Air Conditioner Unit Image

Air Conditioner Unit

Air Conditioner Unit Photo

Air Conditioner Unit

Air Conditioner Unit Photo

Air Conditioner Unit

Air Conditioner Unit Image

Air Conditioner Unit

Air Conditioner Unit Picture


Viewing all articles
Browse latest Browse all 5

Latest Images

Trending Articles





Latest Images